Metabo Compressor Pump Classic 8 Operations Instructions Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
14
ENGLISH
9. Technical Specifications
Suction capacity l/min 220
Free air delivery (volume flow rate) l/min 100
Filling rate l/min 110
Max. working pressure bar 8
Max. storage / operating temperature *) °C + 40
Min. storage / operating temperature **) °C + 5
Pressure vessel volume l 24
No. of air outlets 2
No. of cylinders 1
Motor speed min
-1
2850
Motor capacity kW 1.5
Supply voltage (50 Hz) V 230
Rated current A 6.7
Fuse protection min. A 10 (time-lag)
Degree of protection IP 20
Maximum total calbe length when using extension cables:
– at 3 x 1.0 mm
2
lead cross-section
– at 3 x 1.5 mm
2
lead cross-section
– at 3 x 2.5 mm
2
lead cross-section
m
m
m
10
25
25
Required oil quantity (pump) l approx. 0.25
Dimensions: length x width x height mm 575 x 310 x 595
Weight kg 27.0
Sound pressure level L
PA
at 1 m maximum dB (A) 82 ± 3
Sound power level L
WA
dB (A) 90
All specifications refer to 20 °C ambient temperature.
*) The service life of certain components, e.g. the gasket in the check valve, is greatly reduced when operating the compressor at
high temperatures (maximum storage/operating temperature and above).
**) At temperatures below the minimum storage/operating temperature there is a risk of the condensate freezing in the pressure
vessel.
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 43 44

Comments to this Manuals