23
ENGLISH
Check cables, plug, outlet and
mains fuse.
Band saw blade wanders off the line
of cut or runs off the band saw
wheels
The band saw blade does not run cor-
rectly on the band saw wheels:
correct tracking (see "Care and
Maintenance").
Band saw blade breaks
Incorrect tension:
correct band saw blade tension (see
"Initial Operation").
Load too high:
reduce pressure against band saw
blade (reduced feed rate).
Incorrect band saw blade:
replace band saw blade (see "Care
and Maintenance"):
Curved cuts =
narrow band saw blade,
Straight cuts =
wide band saw blade.
Band saw blade warped
Load too high:
avoid lateral pressure on the band
saw blade.
Saw vibrates
Insufficient mounting:
Fasten saw properly to a suitable
surface (see "Initial operation").
Saw table loose:
align and fasten saw table.
Motor mount loose:
check fastening screws, tighten if
necessary.
Dust extraction port blocked
No dust collector connected or suction
capacity insufficient:
connect a dust collector or increase
suction capacity (air speed 20 m/
sec at dust extraction port).
13. Technical Specifications
Voltage V 230 (1~ 50 Hz)
Nominal current A 1.56
Fuse protection A 10 (MCB type B characteristic)
Protection class IP 44
Degree of protection I
Capacity power input P1
effective shaft output P2
kW
kW
0.35
0.26
Rated no-load speed min
-1
1470 ±10%
Cutting speed m/min 690 ±10%
Band saw blade length mm 1712
Max. throat capacity mm 245
Max. capacity under guide mm 100
Max. band saw blade width mm 12.7
Max. band saw blade thickness mm 0.5
Dimensions
Machine in packing
Length
Width
Height
Machine ready for work (saw table horizontal)
Length
Width
Height
Saw table only
Length
Width
mm
mm
mm
mm
mm
mm
mm
mm
430
340
880
525
425
840
340
340
Weight Machine in packing
Machine ready for work (with accessories supplied)
kg
kg
36.2
32.5
Permissible ambient temperature for operation
Permissible temperature for transport and storage
° C
° C
0 to + 40
0 to +40
Noise emission values (EN 61029-1*), idle running,
A-sound pressure level L
pA
A-sound power level L
WA
Uncertainty K
dB (A)
dB (A)
dB (A)
68.7
72.0
4.0