Compressor does not run:
No mains voltage.
Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
Use only extension cables with
sufficient lead cross section (see
"Technical specifications"). Avoid
using extension cable when
device is cold.
Compressor was stopped by
unplugging.
Switch compressor OFF at the
On/Off switch, then ON again.
Motor protection tripped, e.g. by
insufficient cooling (cooling fins cov
-
ered).
Switch compressor OFF at the
On/Off switch; remove cause for
overheating; let cool off for
approx. 10 minutes; reset the
motor protection switch; switch
compressor ON again at the On/
Off switch.
Compressor runs but does not build
up sufficient pressure.
Condensate drain of pressure ves-
sel leaky.
Check gasket of drain cock(s);
replace if necessary.
Tighten drain cock(s) fingertight.
Drain cock on cup of filter/regulator
unit open.
Tighten drain screw fingertight.
Check valve leaky.
Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
Pressure regulator not opened wide
enough.
Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
Check air hoses, replace defec-
tive parts if necessary.
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
The machine's packaging can be 100 %
recycled.
Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
These instructions are printed on chlo-
rine-free bleached paper.
8. Repairs
9. Environmental protection
10. Technical specifications
Suction capacity l/min 330
Free air delivery (volume flow rate) l/min 190
Filling rate l/min 220
Working pressure (compression end pressure) bar 10
Pressure vessel volume l 50
No. of air outlets 2
Compressor pump model B 2800 B
No. of cylinders 2
Speed (compressor pump) min
-1
1499
Motor capacity kW 2.2
Supply voltage (50 Hz) V 230
Rated current A 10
Fuse protection min. A 16 (time-lag)
Degree of protection IP 44
Maximum overall length when using extension cables with:
– 3 x 1.5 mm
2
lead cross-section
– 3 x 2.5 mm
2
lead cross-section
m
m
30
50
Oil grade 10 W 40
Oil qantity for oil change l 0.21
Dimensions: length x width x height cm 88 x 49 x 77
Weight kg 54
Sound pressure level L
PA
at 4 m maximum dB (A) 73 ± 3
Sound power level L
WA
dB (A) 93 ± 3