Metabo TDP 7500 S User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 39
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
11
ENGLISH
Ensure there is a sufficient water
supply.
Make sure the float switch can
move unrestricted.
Motor hums but does not start:
x Pump blocked by foreign object.
Clean pump.
Pump does not pump properly:
x Delivery head too high.
Observe max. delivery head (see
"Technical Specifications").
x Discharge hose kinked.
Straighten discharge hose.
x Discharge hose leaky.
Seal discharge hose, tighten
screw fittings.
Pump runs very noisy:
x Pump primes air.
Ensure there is a sufficient water
supply.
Adjust float switch correctly.
Hold pump at an angle when sub-
merging.
Pump runs continuously:
x Float switch does not reach lower
position.
Make sure the float switch can
move unrestricted.
A
Danger!
Repairs to electric tools must
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
The packaging of the pump can be
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
9. Repairs
10. Environmental Protection
11. Technical Specifications
Mains voltage V 230 a 1
Frequency Hz 50
Rated output W 1000
Rated current A 4.4
Fuse protection min. (time-lag or L-type circuit breaker) A 10
Running capacitor PF 12.5
Rated speed min
-1
2800
Pump capacity max. l/h 7500
Delivery head max. m 36
Delivery pressure max. bar 3.6
Immersion depth max. m 10
Standing water max. mm 30
Temperature of the primed medium max. °C 35
Degree of protection IP 68
Protection class I
Insulation class B
Materials
Pump casing
Pump shaft
Impeller
Polypropylene
Stainless steel
Noryl
Power cable (HO 7 RN-F) m 15
Discharge port (AG=male, IG=female) 1" IG
Dimensions (pump casing)
Height
Diameter
mm
mm
470
150
Weight kg 8.2
Max. length of extension cable
at 3 x 1.0 mm
2
lead cross-section
at 3 x 1,5 mm
2
lead cross-section
m
m
30
50
Page view 10