User Responsibility
This appliance will perform in conformity with the description contained in the instructions provided. This appli-
ance must be checked periodically. Defective equipment (including power cable) should not be used. Parts that
are broken, missing, obviously worn, distorted or contaminated, should be replaced immediately.
Should such repair become necessary, it is recommended that such repairs are carried out by quali ed persons
approved by metabo or its representatives. This appliance or any of its parts should not be altered or changed
from standard speci cations. The user of this appliance shall have the sole responsibility for any malfunction
which results from improper use or unauthorized modi cation from standard speci cation, faulty maintenance,
damage or improper repair by anyone other than quali ed persons approved by metabo or its representatives.
1 Speci cations
P 600/1600 W P 600/1600 D
Capacity, max.:
9 m³/h 9 m³/h
Suction head, max.:
9 m 9 m
Delivery head, max.:
60 m 60 m
Voltage:
230 V ~ 50Hz 3~230 V - 50 Hz
3~400 V -
Y
50Hz
Motor capacity:
1,6 kW 1,6 kW
Motor speed:
2800 min
-1
2800 min
-1
Protection class:
IP 44 IP 44
Mains fuse:
16 A 16 A
Number of impellers:
22
Self priming:
ja ja
Motor shaft:
Edelstahl Edelstahl
Suction port size:
1 ½" 1 ½"
Discharge port size:
1" 1"
Stock-no.
025 006 0009 025 006 0017
2 General
Please read these instructions carefully before operating this centrifugal pump. Failure to comply with the instruc-
tions provided, negligence or improper handling invalidate the manufacturer's warranty.
The self-priming centrifugal pumps P 600/1600 W and P 600/1600 D have a large delivery capacity at only mini-
mal power consumption. They are used primarily for general water transfer and recirculation, pond and excavati-
on draining, barrel pumping etc. Undesirable constituents like sediment, ne sand or silt are abrasive and dama-
ge the duocone seal. Use of a ne lter is recommended.
Caution: Sand/silt damage the pump's seals. Undesirable constituents like sand, silt, dirt or other solid mat-
ter in the water must be kept from entering the pump by installing a fi lter in the suction line.
This fi lter prevents damage to the pump.