Metabo 170-230 Specifications Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 17
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
4 Installing the Wire Spool
4.1 Disconnect from power mains
Place wire spool onto spool carrier so that wire runs off clockwise.
Central coupling KZ 2
for welding gun
Wire feed regulator
Weld time pot
Dwell time pot
Welding mode selector
(E-models only)
Welding step selector
Neon Control Light
Mains on/off switch
Earth cable socket
230 V/ 400 V
Combi Machines
Combi models come with a CEE 3-phase 5 prong plug
fitted to power cord as standard, and an adaptor with
1-phase plug.
If a 3-phase plug matching your local standard outlet
has to be installed, connection has to be made to 2
phases, neutral and earth.
For 380/415 V operation
connect to 2 phases + zero
and earth lead
L1 black
L2 brown
earth lead yellow/green
zero/neutal lead blue
Caution: Have machine connected to power mains by a qualified electrician only!