11
O-rings damages or soiled
Clean or replace O-rings,
tighten screws fully
A. Air escapes between lid and housing:
Trouble shooting
Faults and possible causes
Remedy
B. Fasteners are not driven all the way in:
Working pressure too low.
Cross section of air hose too small.
Tool without lubrication
ncrease air pressure in 0.5 bar increments,
until fasteners are properly driven.
Min. 6 mm inner diameter required.
Clean parts and lubricate.
C. Fasteners are driven too far into the material
Working pressure too high.
Reduce working pressure in
steps of 0.5 bar.
D. Fasteners project or are bend:
Tool not held down firmly enough.
Hold down tool more firmly or increase
working pressure, if necessary.