115 162 4029 / 0803 - 3.2BedienungsanleitungOperating InstructionsInstructions de serviceGebruiksaanwijzingInstrucciones de usoInvert 130/40Invert 130
9 Safety Precautions/Accident Prevention- This Welding Machine should only be used for its intended application (TIG and manual arc welding).- Operate
10 Wiring Diagram Invert 130/40 and 130/60(2)(5)(6)(1)(7)(3)(1) Power cable(2) Switch/plug(3) Control PCB(4) Transformer(5) Diodes(6) Choke(7) Fan(4)1
D DEUTSCH ENG ENGLISHKONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITYWir erklären in alleiniger Verantwortlichkeit, dass dieses Produkt mit den folg
Country; Company; Address 1; Address 2; City; Phone; Fax; E-mailAlbania; Extra Industrial Goods; Rl. Fadil Rada 88; ; Tirana; (+355) 42 - 3 30
ENGTable of Contents1 Technical Specifications2 Scope of Application2.1 Information3 Commissioning4 Description5 Operation6 TIG-Welding (optional)6.1
2.1 Information - Shown On Type PlateThe following explanations refer to the numbered boxes shown in Figure 2.3 according to ISO/IEC 60974-1.a) Identi
b) Welding OutputBox 6 Welding process Symbol e.g.:Manual metal arc welding with covered electrodesTungsten inert-gas weldingMetal inert and active ga
Column a) need not be used if the duty cycle (duty factor) for the rated maximum weldingcurrent is 60 % or 100 %.Column b) need not be used if the dut
5 OperationThe welding machines Invert 130/40 and 130/60 are primary clocked inverters, suitable for manual arc welding withcoated stick electrodes an
Dust, dirt and metal chips will harm any welding machine. It is of particular importance that the air ventilation forcooling is not disabled.Prior to
The correct arc length is important for a good weld, because with too short or too long an arc both welding current andworking voltage change. A low w
6 TIG Welding (optional)Due to the same welding characteristics as with manual arc welding, TIG welding is possible with models Invert130/40 and 130/6