ENGLISH
4.2 Mains Connection
A
Danger! High voltage
Operate machine in dry environment
only.
Operate machine only on a power
source complying with the following
requirements:
outlets properly installed, earthed
and tested;
fuse protection in accordance
with the Technical Specifications.
Position power cable so it does not
interfere with the work and is not
damaged.
Always check to see that the machine
is switched OFF before plugging in.
Protect power cable from heat,
aggressive liquids and sharp edges.
Use only extension cables with suffi-
cient lead cross section (see "Techni-
cal Specifications").
Do not stop the compressor by
unplugging, but switch OFF using the
switch.
Unplug after use.
4.3 Generating compressed
air
1. Start compressor (28) and wait until
the max. tank pressure is reached
(compressor shuts off).
The tank pressure is indicated by
the tank pressure gauge (32).
2. Set pressure regulator (29) to
required working pressure. The cur-
rent working pressure is indicated
by the regulated pressure gauge
(31).
A
Caution!
The regulated pressure may not be
set higher than the max. working
pressure of the connected air tools!
3. Connect air hose to compressed air
outlet (30).
4. Connect air tool.
You are now ready to work with the
air tool.
5. Switch the compressor OFF (28), if
you do not continue working imme-
diately afterwards. Unplug after
switching OFF.
A
Danger!
Prior to all servicing:
Switch Off.
Unplug.
Wait until the compressor has
come to a complete stop.
Ensure the compressor and all air
tools and accessories connected
to it are relieved from pressure.
Let the device and all air tools
and accessories used cool off.
After all servicing:
Check to see that all safety
devices are operational.
Make sure that no tools or other
parts remain on or in the
machine.
Repair and maintenance work other
than described in this section must
only be carried out by qualified spe-
cialists.
5.1 Periodic maintenance
A
Caution!
Überprüfen Sie am neuen Verdichter
die Anzugsmomente der Zylinderko-
pfschrauben (siehe "Technische
Daten") nach den ersten 50 und 250
Betriebsstunden.
Prior to each use
Check air hoses for damage,
replace if necessary.
Check all screwed connections for
tightness, tighten if necessary.
Check power supply cable for dam-
age, if necessary have replaced by
a qualified electrician.
Every 50 operating hours
Check air filter element (33) of com-
pressor pump, clean if necessary.
Check oil level of pump at oil sight
glass (34), top up oil if necessary.
Drain condensate from pressure
vessel (35).
A
Caution!
Das Kondenswasser enthält Öl und
muss über eine Problemstoff-Sam-
melstelle entsorgt werden.
Every 250 operating hours
Replace air intake filter element of
compressor pump.
Every 500 operating hours
Öl des Verdichters ablassen und
erneuern.
Every 1000 operating hours
Have unit serviced by an authorized
service station. This will extent the
compressor's service life considera-
bly.
5.2 Machine storage
1. Switch unit OFF and unplug.
2. Release pressure from tank and all
connected air tools.
3. Store machine in such way that it
cannot be started by unauthorized
persons.
A
Caution!
Do not store machine unprotected
outdoors or in damp environment.
Do not lay device on its side for trans-
portation or storing.
A
Danger!
Prior to all servicing:
Switch Off.
Unplug.
30
31
28
29
32
5. Care and Maintenance
33
6. Trouble Shooting