Metabo P 600 Operations Instructions Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
GB
7
User Responsibility
This appliance will perform in conformity with the description contained in the instructions provided. This appliance
must be checked periodically. Defective equipment (including power cable) should not be used. Parts that are
broken, missing, obviously worn, distorted or contaminated, should be replaced immediately.
Should such repair become necessary, it is recommended that such repairs are carried out by qualified persons
approved by metabo or its representatives. This appliance or any of its parts should not be altered or changed from
standard specifications. The user of this appliance shall have the sole responsibility for any malfunction which
results from improper use or unauthorized modification from standard specification, faulty maintenance, damage
or improper repair by anyone other than qualified persons approved by metabo or its representatives.
3 Connection to Power Mains
The metabo centrifugal pump P 600/1600 W is safety earthed and must be connected to an earthed single-phase
outlet providing 230 VAC 50 Hz power. The circuit should be protected with a min. 16 A fuse.
The Elektra Beckum centrifugal pump P 600/1600 D is safety earthed and must be connected to an earthed three-
phase outlet providing 400 VAC 50 Hz power. The circuit should be protected with a min. 16 A fuse.
It is recommended to operate this appliance on a residual current device (RCD) of 30 mA capacity.
Damaged power cables must be replaced by a qualified electrician or authorized service centres. Keep grade
H 07 RN-F 3G 1.0 mm˝ or similar.
Operating this device with a damaged electrical cable is dangerous. Danger of personal injury!
When this device is used near swimming pools or garden ponds adhere to all relevant legislation. If in doubt consult
a qualified electrician.
A defective pump should be taken out of service immediately, as water leakage may cause damages.
- Pull plug from socket if unit is not in use (holidays, weekend homes etc.).
- Children and juveniles should not operated this device.
- Use only genuine Elektra Beckum spare parts for repairs.
1 Specifications P 600/1600 W P 600/1600 D
Capacity max. 9 m
3
/h max. 9 m
3
/h
Suction head max. 9 m max. 9 m
Delivery head max. 60 m max. 60 m
Voltage 230 V ~ 50 Hz 3~ 230 V Δ 50 Hz
3~ 400 V 50 Hz
Motor capacity 1.6 kW 1.6 kW
Motor speed 2800 min
-1
2800 min
-1
Protection class IP 44 IP 44
Mains fuse 16 A 16 A
Number of impellers 2 2
Self priming yes yes
Motor shaft stainless steel stainless steel
Suction port size 1 1/2" 1 1/2"
Discharge port size 1" 1"
Stock-no. 025 006 0009 025 006 0017
2 General
Please read these instructions carefully before operating this centrifugal pump. Failure to comply with the
instructions provided, negligence or improper handling invalidate the manufacturer's warranty.
The self-priming centrifugal pumps P 600/1600 W and P 600/1600 D have a large delivery capacity at only minimal
power consumption. They are used primarily for general water transfer and recirculation, pond and excavation
draining, barrel pumping etc. Undesirable constituents like sediment, fine sand or silt are abrasive and damage the
duocone seal. Use of a fine filter is recommended.
Due to their high suction capacity both models have a good priming characteristic and a short priming time.
If the level difference between suction head and delivery head is more than 5 metres, use of a suction tube with
a diameter larger than the diameter of the suction port is required.
Caution: Sand/silt damage the pump's seals. Undesirable constituents like sand, silt, dirt or other solid matter
in the water must be kept from entering the pump by installing a filter in the suction line.
This filter prevents damage to the pump.
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments