15
ENGLISH
• Motor protection tripped, e.g. by
insufficient cooling (cooling fins cov
-
ered).
− Switch compressor OFF at the
On/Off switch; remove cause for
overheating; let cool off for
approx. 10 minutes; reset the
motor protection switch; switch
compressor ON again at the On/
Off switch.
Compressor runs but does not build
up sufficient pressure.
• Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain cock(s);
replace if necessary.
− Tighten drain cock(s) fingertight.
• Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
• Pressure regulator not opened wide
enough.
− Open pressure regulator more.
• Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun
-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
The machine's packaging can be 100 %
recycled.
Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
These instructions are printed on chlo-
rine-free bleached paper.
8. Repairs
9. Environmental protection
10. Technical specifications
Suction capacity l/min 290
Free air delivery (volume flow rate) l/min 165
Filling rate l/min 195
Working pressure (compression end pressure) bar 10
Pressure vessel volume l 50
No. of air outlets 2
Compressor pump model B 2800
No. of cylinders 2
Speed (compressor pump) min
-1
1300
Motor capacity kW 2.0
Supply voltage (50 Hz) V 400
Rated current A 3.7
Fuse protection min. A 10 (time-lag)
Degree of protection IP 44
Maximum overall length when using extension cables with:
– 3 x 1.5 mm
2
lead cross-section
– 3 x 2.5 mm
2
lead cross-section
m
m
100
160
Oil grade 10 W 40
Oil qantity for oil change l 0.21
Dimensions: length x width x height cm 88 x 49 x 77
Weight kg 46
Sound pressure level L
PA
at 4 m maximum dB (A) 71 ± 3
Sound power level L
WA
dB (A) 91 ± 3
Comments to this Manuals